+90 505 916 81 96 info@barotech.com.tr
Request a quote
PRIME 4: a four-person chamber with a rounded light-grey body and black ribs.

PRIME

1–4 persons3.0 ATAØ1000 mm viewportPRIME 1 / PRIME 2 / PRIME 3 / PRIME 4

Chambers for 1 to 4 persons fitted with leather seats, personal screens and a wide acrylic viewport. 3.0 ATA working pressure.

WellnessPremium hyperbaric chamber systems for 1 to 4 persons

PRIME has a 2100 × 2100 mm section; its length runs from 1500 mm to 4500 mm depending on the number of persons. Reclining leather seats, 24" smart TVs and 3D headsets are standard. The fire suppression system complies with NFPA 99 and the air supply with EN 12021.

PRIME interior: a row of black leather seats and light lines.

A lounge, not a treatment cubicle

Leather seats with adjustable recline and leg raise, leather-upholstered surfaces and ambient lighting. Every seat has an armrest, cupholder and table.

Screens and round viewports inside PRIME.

A screen for everyone

A 24" smart TV and a 3D headset per person are standard. A 10" tablet for every seat is optional.

The PRIME door and round viewport seen from inside.

A one-metre window

A Ø1000 mm acrylic viewport and two Ø250 mm viewports open the interior to the room outside.

The system that comes with the chamber

PRIME is more than a hull. Every subsystem below is built by Barotech, tested together and delivered together.

PRIME system diagramAir supply, fire suppression and the optional oxygen system connect to the chamber; the operator console runs it.Air supplyStandardFire suppressionStandardbar0conOptionalPRIMEChamberOperator consoleStandard
  • Chamber
    2100 × 2100 mm section, 1–4 persons, 1500–4500 mm long.
  • Air supply
    Compressor, dryer, filter group, 500–1000 L stainless tank.
  • Fire suppression
    Water tank, smoke and UV flame detectors. NFPA 99 compliant.
  • Operator console
    24" information and warning screens, 10" touch control, 30-minute UPS.
  • bar0con Optional
    PSA oxygen concentrator, 95 ±1% purity, 10 L/min.

Within reach of the operator and the user

The session is run from the console outside; the panels inside show the same information.

A single PRIME seat with its personal screen.

Seating and upholstery

  • Leather seat with adjustable recline and leg raise
  • Armrest, cupholder and table
  • Fire-retardant fabric and filling
  • Leather-upholstered interior surfaces

Safety systems

  • In an emergency the chamber is vented within two minutes
  • Manual exit valves inside and outside
  • Fire suppression with smoke and UV flame detectors
  • An emergency button and monitoring camera for every seat

Technical specifications

Values are taken from the Barotech 2026 catalogue. Values specific to your project come with the quote.

Values common to PRIME 1, PRIME 2, PRIME 3, PRIME 4
Maximum operating pressure 2.0 bar (3.0 ATA)
Design pressure 2.2 bar (3.2 ATA)
Hydrostatic test pressure 3.3 bar (4.3 ATA)
Capacity 1–4 persons
Total length 1500–4500 mm
Total height 2100 mm
Total width 2100 mm
Chamber weight 2,950–5,800 kg ±10%
Doors 1 × 1700 × 700 mm quantity × height × width
Viewports 1 × Ø1000 mm + 2 × Ø250 mm PMMA

Equipment and subsystems

Every system below is in the standard scope. Optional items are shown separately.

Premium seating and upholstery

Leather comfort seats with adjustable recline and leg raise, armrest, cupholder and table. Interior surfaces are upholstered in leather.

Entertainment system

A 24" smart TV and a 3D headset per person, with internet connectivity.

Control panel and operator console

Oxygen and CO₂ analysers, 24" information and warning screens, a 10" control touchscreen, two-way intercom and a 30-minute uninterruptible power supply.

Air supply system

A low-pressure compressor, air dryer, a filter group ending in a bacterial filter, and a 500–1000 L stainless steel air tank. EN 12021 compliant.

Fire suppression and emergency exit

A stainless water tank, smoke and UV flame detectors, and an NFPA 99 compliant spray system. In an emergency the chamber is vented within two minutes.

Breathing and monitoring

A BIBS regulator and medical oxygen mask per person, emergency button, monitoring camera and video recorder.

PRIME 1: single-person chamber.
PRIME 2: two-person chamber.
PRIME 3: three-person chamber.

Certifications

PRIME systems are designed, manufactured and tested to the certificates and standards below.

Company certificates

93/42/EEC
Medical CE. Notified body Szutest (CE 2975). In transition to MDR 2017/745.
ISO 13485
Medical devices quality management
ISO 9001
Quality management
ISO 14001
Environmental management
ISO 45001
Occupational health and safety

Product-specific tests

2014/68/EU
Pressure Equipment Directive (PED)
NFPA 99
Hyperbaric fire suppression system
EN 60601-1
Medical electrical equipment
Intertek · TÜV NORD
Third-party inspection

Design and manufacturing standards

EN 14931
Pressure vessels for human occupancy
ASME PVHO-1
Safety standard for pressure vessels for human occupancy
EN 13445
Unfired pressure vessels
AD 2000
Merkblatt pressure vessel code
EN 12021
Breathing air quality
ISO 25051
Software quality requirements

Questions about PRIME

If your question is not answered here, write to us.

What is the difference between PRIME 1, 2, 3 and 4?

The number of persons and, with it, length and weight. Section (2100 × 2100 mm), door size and working pressure are common to all four.

Where does the oxygen come from?

From your facility's oxygen line, or from the optional bar0con PSA concentrator. bar0con produces 10 L/min at 95 ±1% purity and has a 150 L integrated tank.

The PRIME door seen from inside.

Get a quote for PRIME.

Tell us the number of persons and your room dimensions, and we will prepare the layout plan and the quote for your project.

info@barotech.com.trTaşköprü Sanayi Bölgesi, 3. Cadde No: 4, Yalova